Siemens Opcenter Execution Foundation
En bref
- Source
- NVD
- EPSS
- EPSS 0.49 % · centile 42 ()
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- siemens
- Statut NVD
- Modified
Rechercher sur…
Description
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.
Faiblesses (CWE)
- CWE-79 — Injection de code indirecte (XSS)
Références
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 3.1 | HIGH 7.1 | CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C | siemens |
| CVSS 3.1 | HIGH 7.1 | CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | MEDIUM 6.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N | NVD · nvd@nist.gov (Primary) |
Références européennes
- ENISA EUVD · EUVD-2023-50507
- GCVE · GCVE-0-2023-46282
Avis du CERT-FR
- CERTFR-2023-AVI-1015 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Configurations affectées (CPE NVD)
cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*< 4.1cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\/automotive:-:*:*:*:*:*:*:*cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*≥ 14.0 < 15cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*≥ 15 < 16cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*≥ 16 < 17cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*≥ 17 < 18cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*
Produits affectés
| Produit | Versions |
|---|---|
| Siemens · Opcenter Execution Foundation | affected 0 < V2407 |
| Siemens · Opcenter Quality | affected 0 < V2312 |
| Siemens · SIMATIC PCS neo | affected 0 < V4.1 |
| Siemens · SINEC NMS | affected 0 < V2.0 SP1 |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V14 | affected 0 < * |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V15.1 | affected 0 < * |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V16 | affected 0 < * |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V17 | affected 0 < V17 Update 8 |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V18 | affected 0 < V18 Update 3 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |