Siemens Opcenter Execution Foundation
At a glance
- Source
- NVD
- EPSS
- EPSS 0.49 % · percentile 42 ()
- State
- PUBLISHED
- Published
- Updated
- Assigner
- siemens
- NVD status
- Modified
Description
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.
Weaknesses (CWE)
- CWE-79 — Improper Neutralization of Input During Web Page Generation
References
Scores
| Version | Score | Vector | Scored by |
|---|---|---|---|
| CVSS 3.1 | HIGH 7.1 | CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C | siemens |
| CVSS 3.1 | HIGH 7.1 | CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | MEDIUM 6.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N | NVD · nvd@nist.gov (Primary) |
European references
- ENISA EUVD · EUVD-2023-50507
- GCVE · GCVE-0-2023-46282
CERT-FR advisories
- CERTFR-2023-AVI-1015 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Affected configurations (NVD CPE)
cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*< 4.1cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\/automotive:-:*:*:*:*:*:*:*cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*≥ 14.0 < 15cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*≥ 15 < 16cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*≥ 16 < 17cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*≥ 17 < 18cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*
Affected products
| Product | Versions |
|---|---|
| Siemens · Opcenter Execution Foundation | affected 0 < V2407 |
| Siemens · Opcenter Quality | affected 0 < V2312 |
| Siemens · SIMATIC PCS neo | affected 0 < V4.1 |
| Siemens · SINEC NMS | affected 0 < V2.0 SP1 |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V14 | affected 0 < * |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V15.1 | affected 0 < * |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V16 | affected 0 < * |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V17 | affected 0 < V17 Update 8 |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V18 | affected 0 < V18 Update 3 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |