Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
At a glance
- Source
- NVD
- EPSS
- EPSS 0.83 % · percentile 58 ()
- State
- PUBLISHED
- Published
- Updated
- Assigner
- siemens
- NVD status
- Modified
Description
A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
Weaknesses (CWE)
- CWE-79 — Improper Neutralization of Input During Web Page Generation
References
Scores
| Version | Score | Vector | Scored by |
|---|---|---|---|
| CVSS 3.0 | MEDIUM 4.8 | CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N | NVD · nvd@nist.gov (Primary) |
| CVSS 2.0 | LOW 3.5 | AV:N/AC:M/Au:S/C:N/I:P/A:N | NVD · nvd@nist.gov (Primary) |
European references
- ENISA EUVD · EUVD-2018-16628
- GCVE · GCVE-0-2018-4842
CERT-FR advisories
- CERTFR-2022-AVI-1094 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
- CERTFR-2018-AVI-279 — Multiples vulnérabilités dans SCADA les produits Siemens · cert.ssi.gouv.fr
Affected configurations (NVD CPE)
cpe:2.3:o:siemens:scalance_x200irt_firmware:*:*:*:*:*:*:*:*< 5.4.1cpe:2.3:o:siemens:scalance_x300_firmware:-:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*< 5.2.3
Affected products
| Product | Versions |
|---|---|
| Siemens · SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) | affected All versions < V5.4.1 |
| Siemens · SCALANCE X-200RNA switch family | affected All versions < V3.2.7 |
| Siemens · SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) | affected All versions < V4.1.3 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |