Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
En bref
- Source
- NVD
- EPSS
- EPSS 0.83 % · centile 58 ()
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- siemens
- Statut NVD
- Modified
Description
A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
Faiblesses (CWE)
- CWE-79 — Injection de code indirecte (XSS)
Références
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 3.0 | MEDIUM 4.8 | CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N | NVD · nvd@nist.gov (Primary) |
| CVSS 2.0 | LOW 3.5 | AV:N/AC:M/Au:S/C:N/I:P/A:N | NVD · nvd@nist.gov (Primary) |
Références européennes
- ENISA EUVD · EUVD-2018-16628
- GCVE · GCVE-0-2018-4842
Avis du CERT-FR
- CERTFR-2022-AVI-1094 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
- CERTFR-2018-AVI-279 — Multiples vulnérabilités dans SCADA les produits Siemens · cert.ssi.gouv.fr
Configurations affectées (CPE NVD)
cpe:2.3:o:siemens:scalance_x200irt_firmware:*:*:*:*:*:*:*:*< 5.4.1cpe:2.3:o:siemens:scalance_x300_firmware:-:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*< 5.2.3
Produits affectés
| Produit | Versions |
|---|---|
| Siemens · SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) | affected All versions < V5.4.1 |
| Siemens · SCALANCE X-200RNA switch family | affected All versions < V3.2.7 |
| Siemens · SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) | affected All versions < V4.1.3 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |