D-Link DIR-868L SSDP Service sub_1BF84 os command injection (D-Link DIR-868L)

CVE-2026-3485
CRITICAL 9.3

At a glance

Source
NVD
EPSS
EPSS 5.31 % · percentile 93 ()
State
PUBLISHED
Published
Updated
Assigner
VulDB
NVD status
Analyzed

Description

A flaw has been found in D-Link DIR-868L 110b03. This affects the function sub_1BF84 of the component SSDP Service. This manipulation of the argument ST causes os command injection. It is possible to initiate the attack remotely. The exploit has been published and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Weaknesses (CWE)

  • CWE-78 — Improper Neutralization of Special Elements used in an OS Command
  • CWE-77 — Improper Neutralization of Special Elements used in a Command

References

Scores

VersionScoreVectorScored by
CVSS 4.0CRITICAL 9.3CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:PVulDB
CVSS 3.1CRITICAL 9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:RVulDB
CVSS 3.0CRITICAL 9.8CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:RVulDB
CVSS 2.0CRITICAL 10.0AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:URVulDB
CVSS 4.0HIGH 8.9CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XNVD · cna@vuldb.com (Secondary)
CVSS 3.1CRITICAL 9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HNVD · cna@vuldb.com (Secondary)
CVSS 2.0HIGH 10.0AV:N/AC:L/Au:N/C:C/I:C/A:CNVD · cna@vuldb.com (Secondary)

European references

Affected configurations (NVD CPE)

Affected products

ProductVersions
D-Link · DIR-868Laffected 110b03