Siemens RUGGEDCOM ROX MX5000

CVE-2025-33025
CRITICAL 9.4

At a glance

Source
NVD
EPSS
EPSS 1.26 % · percentile 70 ()
State
PUBLISHED
Published
Updated
Assigner
siemens
NVD status
Deferred

Description

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'traceroute' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.

Weaknesses (CWE)

  • CWE-602 — Client-Side Enforcement of Server-Side Security

References

Scores

VersionScoreVectorScored by
CVSS 3.1CRITICAL 9.9CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:Hsiemens
CVSS 4.0CRITICAL 9.4CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:Hsiemens
CVSS 4.0CRITICAL 9.4CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XNVD · productcert@siemens.com (Secondary)
CVSS 3.1CRITICAL 9.9CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:HNVD · productcert@siemens.com (Secondary)

European references

Affected products

ProductVersions
Siemens · RUGGEDCOM ROX MX5000affected 0 < V2.16.5
Siemens · RUGGEDCOM ROX MX5000REaffected 0 < V2.16.5
Siemens · RUGGEDCOM ROX RX1400affected 0 < V2.16.5
Siemens · RUGGEDCOM ROX RX1500affected 0 < V2.16.5
Siemens · RUGGEDCOM ROX RX1501affected 0 < V2.16.5
Siemens · RUGGEDCOM ROX RX1510affected 0 < V2.16.5
Siemens · RUGGEDCOM ROX RX1511affected 0 < V2.16.5
Siemens · RUGGEDCOM ROX RX1512affected 0 < V2.16.5
Siemens · RUGGEDCOM ROX RX1524affected 0 < V2.16.5
Siemens · RUGGEDCOM ROX RX1536affected 0 < V2.16.5
Siemens · RUGGEDCOM ROX RX5000affected 0 < V2.16.5

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD