Siemens Automation License Manager V6.0

CVE-2025-30033
HIGH 8.5

En bref

Source
NVD
EPSS
EPSS 0.21 % · centile 11 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
siemens
Statut NVD
Deferred

Description

The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.

Faiblesses (CWE)

  • CWE-427 — Élément de chemin de recherche non maîtrisé

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1HIGH 7.8CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsiemens
CVSS 4.0HIGH 8.5CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:Nsiemens
CVSS 4.0HIGH 8.5CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XNVD · productcert@siemens.com (Secondary)
CVSS 3.1HIGH 7.8CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HNVD · productcert@siemens.com (Secondary)

Références européennes

Avis du CERT-FR

Produits affectés

ProduitVersions
Siemens · Automation License Manager V6.0affected 0 < *
Siemens · Automation License Manager V6.2affected 0 < V6.2 Upd3
Siemens · CEMAT V10.0affected 0 < *
Siemens · CP PtP Param configuring interfaceaffected 0 < *
Siemens · Create MyConfig (CMC)affected 0 < V6.9
Siemens · Energy Support Library (EnSL)affected 0 < *
Siemens · FM Configuration Packageaffected 0 < *
Siemens · Modular PID CTRL Toolaffected 0 < *
Siemens · MultiFieldbus Configuration Tool (MFCT)affected 0 < V1.5.5.0
Siemens · OpenPCS 7 V10.0affected 0 < *
Siemens · OpenPCS 7 V9.1affected 0 < *
Siemens · Siemens Network Planner (SINETPLAN)affected 0 < V2.0 SP2
Siemens · SIMATIC Automation Toolaffected 0 < V5.0 SP4
Siemens · SIMATIC Automation Tool SDK Windowsaffected 0 < V5.0 SP4
Siemens · SIMATIC BATCH V10.0affected 0 < *
Siemens · SIMATIC BATCH V9.1affected 0 < *
Siemens · SIMATIC Control Function Library (CFL) V1.xaffected 0 < *
Siemens · SIMATIC Control Function Library (CFL) V2.xaffected 0 < *
Siemens · SIMATIC Control Function Library (CFL) V3.xaffected 0 < V3.1.0.2
Siemens · SIMATIC Control Function Library (CFL) V4.xaffected 0 < V4.1

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD