Siemens SINEMA Remote Connect Client
At a glance
- Source
- NVD
- EPSS
- EPSS 1.03 % · percentile 64 ()
- State
- PUBLISHED
- Published
- Updated
- Assigner
- siemens
- NVD status
- Modified
Description
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an administrative remote attacker running a corresponding SINEMA Remote Connect Server to execute arbitrary code with system privileges on the client system.
Weaknesses (CWE)
- CWE-77 — Improper Neutralization of Special Elements used in a Command
References
Scores
| Version | Score | Vector | Scored by |
|---|---|---|---|
| CVSS 3.1 | MEDIUM 6.6 | CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C | siemens |
| CVSS 4.0 | HIGH 7.5 | CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N | siemens |
| CVSS 4.0 | HIGH 7.5 | CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | MEDIUM 6.6 | CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | HIGH 7.2 | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H | NVD · nvd@nist.gov (Primary) |
European references
- ENISA EUVD · EUVD-2024-38093
- GCVE · GCVE-0-2024-39569
Affected configurations (NVD CPE)
cpe:2.3:a:siemens:sinema_remote_connect_client:*:*:*:*:*:*:*:*< 3.2cpe:2.3:a:siemens:sinema_remote_connect_client:3.2:-:*:*:*:*:*:*
Affected products
| Product | Versions |
|---|---|
| Siemens · SINEMA Remote Connect Client | affected 0 < V3.2 HF1 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |