Junos OS: EX4300 Series: Loopback filter not blocking traffic despite having discard term. (Juniper Networks Junos)

CVE-2024-30410
MEDIUM 6.9

At a glance

Source
NVD
EPSS
EPSS 0.36 % · percentile 30 ()
State
PUBLISHED
Published
Updated
Assigner
juniper
NVD status
Analyzed

Description

An Incorrect Behavior Order in the routing engine (RE) of Juniper Networks Junos OS on EX4300 Series allows traffic intended to the device to reach the RE instead of being discarded when the discard term is set in loopback (lo0) interface. The intended function is that the lo0 firewall filter takes precedence over the revenue interface firewall filter.  This issue affects only IPv6 firewall filter. This issue only affects the EX4300 switch. No other products or platforms are affected by this vulnerability.  This issue affects Juniper Networks Junos OS: * All versions before 20.4R3-S10, * from 21.2 before 21.2R3-S7, * from 21.4 before 21.4R3-S6.

Weaknesses (CWE)

  • CWE-696 — Incorrect Behavior Order

References

Scores

VersionScoreVectorScored by
CVSS 3.1MEDIUM 5.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:Njuniper
CVSS 4.0MEDIUM 6.9CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:L/SA:Njuniper
CVSS 4.0MEDIUM 6.9CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XNVD · sirt@juniper.net (Secondary)
CVSS 3.1MEDIUM 5.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:NNVD · sirt@juniper.net (Secondary)

European references

CERT-FR advisories

Affected configurations (NVD CPE)

Affected products

ProductVersions
Juniper Networks · Junosaffected 0 < 20.4R3-S10 ; affected 21.2 < 21.2R3-S7 ; affected 21.4 < 21.4R3-S6

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD