Siemens SIMATIC RTLS Locating Manager
En bref
- Source
- NVD
- EPSS
- EPSS 0.84 % · centile 58 ()
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- siemens
- Statut NVD
- Deferred
Description
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected systems use symmetric cryptography with a hard-coded key to protect the communication between client and server. This could allow an unauthenticated remote attacker to compromise confidentiality and integrity of the communication and, subsequently, availability of the system. A successful exploit requires the attacker to gain knowledge of the hard-coded key and to be able to intercept the communication between client and server on the network.
Faiblesses (CWE)
- CWE-321 — Utilisation d'une clé cryptographique codée en dur
Références
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 3.1 | CRITICAL 10.0 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C | siemens |
| CVSS 4.0 | CRITICAL 10.0 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H | siemens |
| CVSS 4.0 | CRITICAL 10.0 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | CRITICAL 10.0 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H | NVD · productcert@siemens.com (Secondary) |
Références européennes
- ENISA EUVD · EUVD-2024-28139
- GCVE · GCVE-0-2024-30207
Produits affectés
| Produit | Versions |
|---|---|
| Siemens · SIMATIC RTLS Locating Manager | affected 0 < V3.0.1.1 |
| Siemens · SIMATIC RTLS Locating Manager | affected 0 < V3.0.1.1 |
| Siemens · SIMATIC RTLS Locating Manager | affected 0 < V3.0.1.1 |
| Siemens · SIMATIC RTLS Locating Manager | affected 0 < V3.0.1.1 |
| Siemens · SIMATIC RTLS Locating Manager | affected 0 < V3.0.1.1 |
| Siemens · SIMATIC RTLS Locating Manager | affected 0 < V3.0.1.1 |
| Siemens · SIMATIC RTLS Locating Manager | affected 0 < V3.0.1.1 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |