Siemens Cerberus PRO EN Engineering Tool

CVE-2024-22041
HIGH 7.5

En bref

Source
NVD
EPSS
EPSS 0.51 % · centile 43 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
siemens
Statut NVD
Deferred

Description

A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems improperly handles memory buffers when parsing X.509 certificates. This could allow an unauthenticated remote attacker to crash the network service.

Faiblesses (CWE)

  • CWE-119 — Opération hors des limites d'un tampon mémoire

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1HIGH 7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csiemens
CVSS 3.1HIGH 7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HNVD · productcert@siemens.com (Secondary)

Références européennes

Avis du CERT-FR

Produits affectés

ProduitVersions
Siemens · Cerberus PRO EN Engineering Toolaffected 0 < *
Siemens · Cerberus PRO EN Fire Panel FC72x IP6affected 0 < *
Siemens · Cerberus PRO EN Fire Panel FC72x IP7affected 0 < *
Siemens · Cerberus PRO EN Fire Panel FC72x IP8affected 0 < IP8 SR4
Siemens · Cerberus PRO EN X200 Cloud Distribution IP7affected 0 < *
Siemens · Cerberus PRO EN X200 Cloud Distribution IP8affected 0 < V4.3.5618
Siemens · Cerberus PRO EN X300 Cloud Distribution IP7affected 0 < *
Siemens · Cerberus PRO EN X300 Cloud Distribution IP8affected 0 < V4.3.5617
Siemens · Cerberus PRO UL Compact Panel FC922/924affected 0 < MP4
Siemens · Cerberus PRO UL Engineering Toolaffected 0 < MP4
Siemens · Cerberus PRO UL X300 Cloud Distributionaffected 0 < V4.3.0001
Siemens · Desigo Fire Safety UL Compact Panel FC2025/2050affected 0 < MP4
Siemens · Desigo Fire Safety UL Engineering Toolaffected 0 < MP4
Siemens · Desigo Fire Safety UL X300 Cloud Distributionaffected 0 < V4.3.0001
Siemens · Sinteso FS20 EN Engineering Toolaffected 0 < *
Siemens · Sinteso FS20 EN Fire Panel FC20 MP6affected 0 < *
Siemens · Sinteso FS20 EN Fire Panel FC20 MP7affected 0 < *
Siemens · Sinteso FS20 EN Fire Panel FC20 MP8affected 0 < MP8 SR4
Siemens · Sinteso FS20 EN X200 Cloud Distribution MP7affected 0 < *
Siemens · Sinteso FS20 EN X200 Cloud Distribution MP8affected 0 < V4.3.5618

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD