Siemens SIMATIC Energy Manager Basic

CVE-2023-52891
MEDIUM 5.3

At a glance

Source
NVD
EPSS
EPSS 0.46 % · percentile 40 ()
State
PUBLISHED
Published
Updated
Assigner
siemens
NVD status
Deferred

Description

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server.

Weaknesses (CWE)

  • CWE-1325 — Improperly Controlled Sequential Memory Allocation

References

Scores

VersionScoreVectorScored by
CVSS 3.1MEDIUM 5.3CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Lsiemens
CVSS 3.1MEDIUM 5.3CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:LNVD · productcert@siemens.com (Secondary)

European references

CERT-FR advisories

Affected products

ProductVersions
Siemens · SIMATIC Energy Manager Basicaffected 0 < V7.5
Siemens · SIMATIC Energy Manager PROaffected 0 < V7.5
Siemens · SIMATIC IPC DiagBaseaffected 0 < *
Siemens · SIMATIC IPC DiagMonitoraffected 0 < *
Siemens · SIMIT V10affected 0 < *
Siemens · SIMIT V11affected 0 < V11.1

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD