Siemens SIMATIC CN 4100

CVE-2023-49251
HIGH 8.8

At a glance

Source
NVD
EPSS
EPSS 0.53 % · percentile 45 ()
State
PUBLISHED
Published
Updated
Assigner
siemens
NVD status
Analyzed

Description

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application allows an attacker to add their own login credentials to the device. This allows an attacker to remotely login as root and take control of the device even after the affected device is fully set up.

Weaknesses (CWE)

  • CWE-639 — Authorization Bypass Through User-Controlled Key

References

Scores

VersionScoreVectorScored by
CVSS 3.1HIGH 8.8CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csiemens
CVSS 3.1HIGH 8.8CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HNVD · productcert@siemens.com (Secondary)
CVSS 3.1HIGH 8.8CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HNVD · nvd@nist.gov (Primary)

European references

CERT-FR advisories

Affected configurations (NVD CPE)

Affected products

ProductVersions
Siemens · SIMATIC CN 4100affected All versions < V2.7

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD