Description

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected software does not correctly validate the response received by an UMC server. An attacker can use this to crash the affected software by providing and configuring a malicious UMC server or by manipulating the traffic from a legitimate UMC server (i.e. leveraging CVE-2023-48427).

Faiblesses (CWE)

  • CWE-754 — Vérification incorrecte de conditions inhabituelles ou exceptionnelles

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1MEDIUM 6.8CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:Csiemens
CVSS 3.1MEDIUM 6.8CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:HNVD · productcert@siemens.com (Secondary)
CVSS 3.1HIGH 8.6CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:HNVD · nvd@nist.gov (Primary)

Références européennes

Avis du CERT-FR

Configurations affectées (CPE NVD)

Produits affectés

ProduitVersions
Siemens · SINEC INSaffected All versions < V1.0 SP2 Update 2