Siemens SINEC INS
En bref
- Source
- NVD
- EPSS
- EPSS 0.45 % · centile 39 ()
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- siemens
- Statut NVD
- Modified
Rechercher sur…
Description
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected products do not properly validate the certificate of the configured UMC server. This could allow an attacker to intercept credentials that are sent to the UMC server as well as to manipulate responses, potentially allowing an attacker to escalate privileges.
Faiblesses (CWE)
- CWE-295 — Validation incorrecte de certificat
Références
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 3.1 | HIGH 8.1 | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C | siemens |
| CVSS 3.1 | HIGH 8.1 | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | CRITICAL 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H | NVD · nvd@nist.gov (Primary) |
Références européennes
- ENISA EUVD · EUVD-2023-52478
- GCVE · GCVE-0-2023-48427
Avis du CERT-FR
- CERTFR-2023-AVI-1015 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Configurations affectées (CPE NVD)
cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*< 1.0cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*
Produits affectés
| Produit | Versions |
|---|---|
| Siemens · SINEC INS | affected All versions < V1.0 SP2 Update 2 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |