Siemens Totally Integrated Automation Portal (TIA Portal) V15
En bref
- Source
- NVD
- EPSS
- EPSS 0.25 % · centile 16 ()
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- siemens
- Statut NVD
- Modified
Rechercher sur…
Description
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.
Faiblesses (CWE)
Références
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 3.1 | HIGH 7.3 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C | siemens |
| CVSS 3.1 | HIGH 7.3 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | HIGH 7.8 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H | NVD · nvd@nist.gov (Secondary) |
Références européennes
- ENISA EUVD · EUVD-2023-30116
- GCVE · GCVE-0-2023-26293
Avis du CERT-FR
- CERTFR-2023-AVI-0298 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Configurations affectées (CPE NVD)
cpe:2.3:a:siemens:tia_portal:15:*:*:*:*:*:*:*cpe:2.3:a:siemens:tia_portal:16:*:*:*:*:*:*:*cpe:2.3:a:siemens:tia_portal:17:-:*:*:*:*:*:*cpe:2.3:a:siemens:tia_portal:17:update1:*:*:*:*:*:*cpe:2.3:a:siemens:tia_portal:17:update2:*:*:*:*:*:*cpe:2.3:a:siemens:tia_portal:17:update3:*:*:*:*:*:*cpe:2.3:a:siemens:tia_portal:17:update4:*:*:*:*:*:*cpe:2.3:a:siemens:tia_portal:17:update5:*:*:*:*:*:*cpe:2.3:a:siemens:tia_portal:18:-:*:*:*:*:*:*
Produits affectés
| Produit | Versions |
|---|---|
| Siemens · Totally Integrated Automation Portal (TIA Portal) V15 | affected 0 < * |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V16 | affected 0 < V16 Update 7 |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V17 | affected 0 < V17 Update 6 |
| Siemens · Totally Integrated Automation Portal (TIA Portal) V18 | affected 0 < V18 Update 1 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |