Siemens SINEC INS

CVE-2022-45094
HIGH 8.4

At a glance

Source
NVD
EPSS
EPSS 1.44 % · percentile 73 ()
State
PUBLISHED
Published
Updated
Assigner
siemens
NVD status
Modified

Description

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially inject commands into the dhcpd configuration of the affected product. An attacker might leverage this to trigger remote code execution on the affected component.

Weaknesses (CWE)

  • CWE-77 — Improper Neutralization of Special Elements used in a Command

References

Scores

VersionScoreVectorScored by
CVSS 3.1HIGH 8.4CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:Csiemens
CVSS 3.1HIGH 8.4CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:HNVD · productcert@siemens.com (Secondary)
CVSS 3.1HIGH 8.8CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HNVD · nvd@nist.gov (Primary)

European references

CERT-FR advisories

Affected configurations (NVD CPE)

Affected products

ProductVersions
Siemens · SINEC INSaffected All versions < V1.0 SP2 Update 1

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD