Siemens Opcenter Quality V13.1
At a glance
- Source
- NVD
- EPSS
- EPSS 1.32 % · percentile 71 ()
- State
- PUBLISHED
- Published
- Updated
- Assigner
- siemens
- NVD status
- Modified
Description
A vulnerability has been identified in Opcenter Quality V13.1 (All versions < V13.1.20220624), Opcenter Quality V13.2 (All versions < V13.2.20220624). The affected applications do not properly validate login information during authentication. This could lead to denial of service condition for existing users or allow unauthenticated remote attackers to successfully login without credentials.
Weaknesses (CWE)
References
Scores
| Version | Score | Vector | Scored by |
|---|---|---|---|
| CVSS 3.1 | HIGH 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H | NVD · nvd@nist.gov (Primary) |
| CVSS 2.0 | MEDIUM 5.0 | AV:N/AC:L/Au:N/C:N/I:N/A:P | NVD · nvd@nist.gov (Primary) |
European references
- ENISA EUVD · EUVD-2022-36775
- GCVE · GCVE-0-2022-33736
CERT-FR advisories
- CERTFR-2022-AVI-627 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Affected configurations (NVD CPE)
cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*≥ 13.1.0 < 13.1.20220624cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*≥ 13.2.0 < 13.2.20220624
Affected products
| Product | Versions |
|---|---|
| Siemens · Opcenter Quality V13.1 | affected All versions < V13.1.20220624 |
| Siemens · Opcenter Quality V13.2 | affected All versions < V13.2.20220624 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |