Siemens SCALANCE W1788-1 M12
En bref
- Source
- NVD
- EPSS
- EPSS 0.37 % · centile 31 ()
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- siemens
- Statut NVD
- Modified
Description
A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature.
Faiblesses (CWE)
- CWE-20 — Validation d'entrée incorrecte
Références
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 3.1 | MEDIUM 6.5 | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H | NVD · nvd@nist.gov (Primary) |
| CVSS 2.0 | LOW 3.3 | AV:A/AC:L/Au:N/C:N/I:N/A:P | NVD · nvd@nist.gov (Primary) |
Références européennes
- ENISA EUVD · EUVD-2022-32781
- GCVE · GCVE-0-2022-28329
Avis du CERT-FR
- CERTFR-2022-AVI-329 — Multiples vulnérabilités dans les produits SIEMENS · cert.ssi.gouv.fr
Configurations affectées (CPE NVD)
cpe:2.3:o:siemens:scalance_w1788-2ia_m12_firmware:*:*:*:*:*:*:*:*< 3.0.0cpe:2.3:o:siemens:scalance_w1788-2_m12_firmware:*:*:*:*:*:*:*:*< 3.0.0cpe:2.3:o:siemens:scalance_w1788-2_eec_m12_firmware:*:*:*:*:*:*:*:*< 3.0.0cpe:2.3:o:siemens:scalance_w1788-1_m12_firmware:*:*:*:*:*:*:*:*< 3.0.0
Produits affectés
| Produit | Versions |
|---|---|
| Siemens · SCALANCE W1788-1 M12 | affected All versions < V3.0.0 |
| Siemens · SCALANCE W1788-2 EEC M12 | affected All versions < V3.0.0 |
| Siemens · SCALANCE W1788-2 M12 | affected All versions < V3.0.0 |
| Siemens · SCALANCE W1788-2IA M12 | affected All versions < V3.0.0 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |