Siemens SICAM PQ Analyzer
En bref
- Source
- NVD
- EPSS
- EPSS 0.83 % · centile 58 ()
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- siemens
- Statut NVD
- Modified
Rechercher sur…
Description
A vulnerability has been identified in SICAM PQ Analyzer (All versions < V3.18). A service is started by an unquoted registry entry. As there are spaces in this path, attackers with write privilege to those directories might be able to plant executables that will run in place of the legitimate process. Attackers might achieve persistence on the system ("backdoors") or cause a denial of service.
Faiblesses (CWE)
- CWE-428 — Chemin de recherche non protégé par des guillemets
Références
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 3.1 | HIGH 8.1 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H | NVD · nvd@nist.gov (Primary) |
| CVSS 2.0 | MEDIUM 5.5 | AV:N/AC:L/Au:S/C:N/I:P/A:P | NVD · nvd@nist.gov (Primary) |
Références européennes
- ENISA EUVD · EUVD-2021-32226
- GCVE · GCVE-0-2021-45460
Avis du CERT-FR
- CERTFR-2022-AVI-018 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Configurations affectées (CPE NVD)
cpe:2.3:o:siemens:sicam_pq_analyzer_firmware:*:*:*:*:*:*:*:*< 3.18
Produits affectés
| Produit | Versions |
|---|---|
| Siemens · SICAM PQ Analyzer | affected All versions < V3.18 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |