Siemens Capital Embedded AR Classic 431-422

CVE-2021-31346
HIGH 8.2

At a glance

Source
NVD
EPSS
EPSS 1.97 % · percentile 80 ()
State
PUBLISHED
Published
Updated
Assigner
siemens
NVD status
Modified

Description

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)

Weaknesses (CWE)

  • CWE-1284 — Improper Validation of Specified Quantity in Input

References

Scores

VersionScoreVectorScored by
CVSS 3.1HIGH 8.2CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:Hsiemens
CVSS 3.1HIGH 8.2CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:HNVD · productcert@siemens.com (Secondary)
CVSS 3.1CRITICAL 9.1CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:HNVD · nvd@nist.gov (Primary)
CVSS 2.0MEDIUM 6.4AV:N/AC:L/Au:N/C:P/I:N/A:PNVD · nvd@nist.gov (Primary)

European references

CERT-FR advisories

Affected configurations (NVD CPE)

Affected products

ProductVersions
Siemens · Capital Embedded AR Classic 431-422affected 0 < *
Siemens · Capital Embedded AR Classic R20-11affected 0 < V2303
Siemens · PLUSCONTROL 1st Genaffected All versions
Siemens · SIMOTICS CONNECT 400affected All versions < V0.5.0.0
Siemens · SIMOTICS CONNECT 400affected All versions < V1.0.0.0

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD