Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)

CVE-2021-25662
HIGH 7.5

At a glance

Source
NVD
EPSS
EPSS 1.67 % · percentile 77 ()
State
PUBLISHED
Published
Updated
Assigner
siemens
NVD status
Modified

Description

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.

Weaknesses (CWE)

  • CWE-755 — Improper Handling of Exceptional Conditions

References

Scores

VersionScoreVectorScored by
CVSS 3.1HIGH 7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HCISA-ADP
CVSS 3.1HIGH 7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HNVD · nvd@nist.gov (Primary)
CVSS 3.1HIGH 7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HNVD · 134c704f-9b21-4f2e-91b3-4a467353bcc0 (Secondary)
CVSS 2.0MEDIUM 5.0AV:N/AC:L/Au:N/C:N/I:N/A:PNVD · nvd@nist.gov (Primary)

European references

CERT-FR advisories

Affected configurations (NVD CPE)

Affected products

ProductVersions
Siemens · SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)affected All versions < V15.1 Update 6
Siemens · SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants)affected All versions < V16 Update 4
Siemens · SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants)affected All versions < V15.1 Update 6
Siemens · SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants)affected All versions < V16 Update 4
Siemens · SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900Faffected All versions < V15.1 Update 6
Siemens · SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900Faffected All versions < V16 Update 4
Siemens · SIMATIC WinCC Runtime Advanced V15affected All versions < V15.1 Update 6
Siemens · SIMATIC WinCC Runtime Advanced V16affected All versions < V16 Update 4

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD