Siemens Opcenter Execution Discrete

CVE-2020-7587
HIGH 8.2

At a glance

Source
NVD
EPSS
EPSS 2.48 % · percentile 85 ()
State
PUBLISHED
Published
Updated
Assigner
siemens
NVD status
Modified

Description

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.

Weaknesses (CWE)

  • CWE-400 — Uncontrolled Resource Consumption

References

Scores

VersionScoreVectorScored by
CVSS 3.1HIGH 8.2CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:LNVD · nvd@nist.gov (Primary)
CVSS 2.0MEDIUM 6.4AV:N/AC:L/Au:N/C:P/I:N/A:PNVD · nvd@nist.gov (Primary)

European references

CERT-FR advisories

Affected configurations (NVD CPE)

Affected products

ProductVersions
Siemens · Opcenter Execution Discreteaffected All versions < V3.2
Siemens · Opcenter Execution Foundationaffected All versions < V3.2
Siemens · Opcenter Execution Processaffected All versions < V3.2
Siemens · Opcenter Intelligenceaffected All versions < V3.3
Siemens · Opcenter Qualityaffected All versions < V11.3
Siemens · Opcenter RD&Laffected V8.0
Siemens · SIMATIC IT LMSaffected All versions < V2.6
Siemens · SIMATIC IT Production Suiteaffected All versions < V8.0
Siemens · SIMATIC Notifier Server for Windowsaffected All versions
Siemens · SIMATIC PCS neoaffected All versions < V3.0 SP1
Siemens · SIMATIC STEP 7 (TIA Portal) V15affected All versions < V15.1 Update 5
Siemens · SIMATIC STEP 7 (TIA Portal) V16affected All versions < V16 Update 2
Siemens · SIMOCODE ES V15.1affected All versions < V15.1 Update 4
Siemens · SIMOCODE ES V16affected All versions < V16 Update 1
Siemens · Soft Starter ES V15.1affected All versions < V15.1 Update 3
Siemens · Soft Starter ES V16affected All versions < V16 Update 1

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD