PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)

CVE-2020-7538
HIGH 7.5

At a glance

Source
NVD
EPSS
EPSS 1.29 % · percentile 70 ()
State
PUBLISHED
Published
Updated
Assigner
schneider
NVD status
Modified

Description

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.

Weaknesses (CWE)

  • CWE-754 — Improper Check for Unusual or Exceptional Conditions

References

Scores

VersionScoreVectorScored by
CVSS 3.1HIGH 7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HNVD · nvd@nist.gov (Primary)
CVSS 2.0MEDIUM 5.0AV:N/AC:L/Au:N/C:N/I:N/A:PNVD · nvd@nist.gov (Primary)

European references

CERT-FR advisories

Affected configurations (NVD CPE)

Affected products

ProductVersions
PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)affected PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0