Siemens SIMATIC CP 1604
At a glance
- Source
- NVD
- EPSS
- EPSS 1.40 % · percentile 72 ()
- State
- PUBLISHED
- Published
- Updated
- Assigner
- siemens
- NVD status
- Modified
Description
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
Weaknesses (CWE)
- CWE-125 — Out-of-bounds Read
References
Scores
| Version | Score | Vector | Scored by |
|---|---|---|---|
| CVSS 3.1 | HIGH 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C | siemens |
| CVSS 3.1 | HIGH 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | HIGH 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H | NVD · nvd@nist.gov (Secondary) |
| CVSS 2.0 | MEDIUM 5.0 | AV:N/AC:L/Au:N/C:N/I:N/A:P | NVD · nvd@nist.gov (Primary) |
European references
- ENISA EUVD · EUVD-2019-16127
- GCVE · GCVE-0-2019-6568
CERT-FR advisories
- CERTFR-2022-AVI-124 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
- CERTFR-2019-AVI-385 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
- CERTFR-2019-AVI-151 — SCADA Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Affected configurations (NVD CPE)
cpe:2.3:o:siemens:cp1604_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:cp1616_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*< 1.1.0cpe:2.3:o:siemens:simatic_cp343-1_advanced_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp443-1_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp443-1_advanced_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*< 2.1.6cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*< 2.7cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*< 15.1cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*< 15.1cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:15.1:-:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*< 15.1cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*< 15.1cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*< 15.1cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*< 15.1cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*< 15.1cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_cp443-1_opc_ua:*:*:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_ipc_diagmonitor:*:*:*:*:*:*:*:*< 5.1.3cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*< 2.7cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:*:*:*:*:*:*:*:*< 2.0cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:2.0:-:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:2.0:sp1:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*< 15.1cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*cpe:2.3:a:siemens:sitop_manager:*:*:*:*:*:*:*:*< 1.1cpe:2.3:o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:*< 3.2.1cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*< 1.1.0cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*< 1.1.0cpe:2.3:o:siemens:simatic_rf182c_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_rf181-eip_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*< 2.6.1- +38 more
Affected products
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |