Siemens SCALANCE S602
At a glance
- Source
- NVD
- EPSS
- EPSS 0.83 % · percentile 57 ()
- State
- PUBLISHED
- Published
- Updated
- Assigner
- siemens
- NVD status
- Modified
Description
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
Weaknesses (CWE)
- CWE-693 — Protection Mechanism Failure
- CWE-1021 — Improper Restriction of Rendered UI Layers or Frames
References
Scores
| Version | Score | Vector | Scored by |
|---|---|---|---|
| CVSS 3.1 | MEDIUM 5.4 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N | NVD · nvd@nist.gov (Primary) |
| CVSS 2.0 | MEDIUM 4.3 | AV:N/AC:M/Au:N/C:N/I:P/A:N | NVD · nvd@nist.gov (Primary) |
European references
- ENISA EUVD · EUVD-2019-5194
- GCVE · GCVE-0-2019-13924
CERT-FR advisories
- CERTFR-2022-AVI-1094 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
- CERTFR-2021-AVI-256 — Multiples vulnérabilités dans les produits Siemens SCALANCE · cert.ssi.gouv.fr
- CERTFR-2020-AVI-090 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Affected configurations (NVD CPE)
cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*< 5.2.4cpe:2.3:o:siemens:scalance_xf-200_firmware:*:*:*:*:*:*:*:*< 5.2.4cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*< 5.2.4cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*< 5.2.4cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*< 4.1.3cpe:2.3:o:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*< 4.1.3cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*< 4.1.3
Affected products
| Product | Versions |
|---|---|
| Siemens · SCALANCE S602 | affected All versions < V4.1 |
| Siemens · SCALANCE S612 | affected All versions < V4.1 |
| Siemens · SCALANCE S623 | affected All versions < V4.1 |
| Siemens · SCALANCE S627-2M | affected All versions < V4.1 |
| Siemens · SCALANCE X-200 switch family (incl. SIPLUS NET variants) | affected All versions < 5.2.4 |
| Siemens · SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) | affected All versions < V5.5.0 |
| Siemens · SCALANCE X-200RNA switch family | affected All versions < V3.2.7 |
| Siemens · SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) | affected All versions < 4.1.3 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |