Siemens AG SINEMA Remote Connect Server
At a glance
- Source
- NVD
- EPSS
- EPSS 0.43 % · percentile 37 ()
- State
- PUBLISHED
- Published
- Updated
- Assigner
- siemens
- NVD status
- Modified
Description
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some parts of the web application are not protected against Cross Site Request Forgery (CSRF) attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a logged-in user to the application. The vulnerability could allow switching the connectivity state of a user or a device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Weaknesses (CWE)
- CWE-352 — Cross-Site Request Forgery
References
Scores
| Version | Score | Vector | Scored by |
|---|---|---|---|
| CVSS 3.1 | MEDIUM 4.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N | NVD · nvd@nist.gov (Primary) |
| CVSS 2.0 | MEDIUM 4.3 | AV:N/AC:M/Au:N/C:N/I:P/A:N | NVD · nvd@nist.gov (Primary) |
European references
- ENISA EUVD · EUVD-2019-5190
- GCVE · GCVE-0-2019-13920
CERT-FR advisories
- CERTFR-2019-AVI-429 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Affected configurations (NVD CPE)
cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*≤ 2.0cpe:2.3:a:siemens:sinema_remote_connect_server:2.0:hf1:*:*:*:*:*:*
Affected products
| Product | Versions |
|---|---|
| Siemens AG · SINEMA Remote Connect Server | affected All versions < V2.0 SP1 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |