Siemens AG SCALANCE SC-600
At a glance
- Source
- NVD
- EPSS
- EPSS 0.41 % · percentile 35 ()
- State
- PUBLISHED
- Published
- Updated
- Assigner
- siemens
- NVD status
- Modified
Description
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.
Weaknesses (CWE)
- CWE-703 — Improper Check or Handling of Exceptional Conditions
References
Scores
| Version | Score | Vector | Scored by |
|---|---|---|---|
| CVSS 3.1 | MEDIUM 6.6 | CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H | NVD · nvd@nist.gov (Primary) |
| CVSS 2.0 | MEDIUM 4.6 | AV:L/AC:L/Au:N/C:P/I:P/A:P | NVD · nvd@nist.gov (Primary) |
European references
- ENISA EUVD · EUVD-2019-2642
- GCVE · GCVE-0-2019-10928
CERT-FR advisories
- CERTFR-2019-AVI-385 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Affected configurations (NVD CPE)
cpe:2.3:o:siemens:scalance_sc-600_firmware:2.0:*:*:*:*:*:*:*
Affected products
| Product | Versions |
|---|---|
| Siemens AG · SCALANCE SC-600 | affected V2.0 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |