Siemens AG RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems, RAPIDLab 1200 Series, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 400 systems

CVE-2018-4845
HIGH 8.8

En bref

Source
NVD
EPSS
EPSS 1.16 % · centile 67 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
siemens
Statut NVD
Modified

Description

A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.

Faiblesses (CWE)

  • CWE-284 — Contrôle d'accès incorrect
  • CWE-269 — Gestion incorrecte des privilèges

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1HIGH 8.8CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HNVD · nvd@nist.gov (Primary)
CVSS 2.0MEDIUM 6.5AV:N/AC:L/Au:S/C:P/I:P/A:PNVD · nvd@nist.gov (Primary)

Références européennes

Avis du CERT-FR

Configurations affectées (CPE NVD)

Produits affectés

ProduitVersions
Siemens AG · RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems, RAPIDLab 1200 Series, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 400 systemsaffected RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems : All versions _without_ use of Siemens Healthineers Informatics products ; affected RAPIDLab 1200 Series : All versions < V3.3 _with_ Siemens Healthineers Informatics products ; affected RAPIDPoint 500 systems : All versions >= V3.0 _with_ Siemens Healthineers Informatics products ; affected RAPIDPoint 500 systems : V2.4.X _with_ Siemens Healthineers Informatics products ; affected RAPIDPoint 500 systems : All versions =< V2.3 _with_ Siemens Healthineers Informatics products ; affected RAPIDPoint 400 systems : All versions_with_ Siemens Healthineers Informatics products

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD