Siemens AG SCALANCE M875

CVE-2018-11447
HIGH 8.8

At a glance

Source
NVD
EPSS
EPSS 0.58 % · percentile 48 ()
State
PUBLISHED
Published
Updated
Assigner
siemens
NVD status
Modified

Description

A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by an legitimate user, who must be authenticated to the web interface as administrative user. A successful attack could allow an attacker to interact with the web interface as an administrative user. This could allow the attacker to read or modify the device configuration, or to exploit other vulnerabilities that require authentication as administrative user. At the time of advisory publication no public exploitation of this security vulnerability was known.

Weaknesses (CWE)

  • CWE-121 — Stack-based Buffer Overflow
  • CWE-352 — Cross-Site Request Forgery

References

Scores

VersionScoreVectorScored by
CVSS 3.0HIGH 8.8CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HNVD · nvd@nist.gov (Primary)
CVSS 2.0MEDIUM 6.8AV:N/AC:M/Au:N/C:P/I:P/A:PNVD · nvd@nist.gov (Primary)

European references

CERT-FR advisories

Affected configurations (NVD CPE)

Affected products

ProductVersions
Siemens AG · SCALANCE M875affected SCALANCE M875 All versions

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD