Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller

CVE-2017-2680
HIGH 7.1

En bref

Source
NVD
EPSS
EPSS 1.15 % · centile 67 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
siemens
Statut NVD
Modified

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1MEDIUM 6.5CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsiemens
CVSS 4.0HIGH 7.1CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:Nsiemens
CVSS 4.0HIGH 7.1CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XNVD · productcert@siemens.com (Secondary)
CVSS 3.1MEDIUM 6.5CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HNVD · productcert@siemens.com (Secondary)
CVSS 3.1MEDIUM 6.5CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HNVD · nvd@nist.gov (Primary)
CVSS 2.0MEDIUM 6.1AV:A/AC:L/Au:N/C:N/I:N/A:CNVD · nvd@nist.gov (Primary)

Références européennes

Avis du CERT-FR

Configurations affectées (CPE NVD)

Produits affectés

ProduitVersions
Siemens · Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controlleraffected All versions < V4.1.1 Patch04
Siemens · Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200affected All versions < V4.2.1 Patch03
Siemens · Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200Paffected All versions < V4.4.0 Patch01
Siemens · Extension Unit 12" PROFINETaffected All versions < V01.01.01
Siemens · Extension Unit 15" PROFINETaffected All versions < V01.01.01
Siemens · Extension Unit 19" PROFINETaffected All versions < V01.01.01
Siemens · Extension Unit 22" PROFINETaffected All versions < V01.01.01
Siemens · IE/AS-i Link PN IOaffected All versions
Siemens · IE/PB-Link (incl. SIPLUS NET variants)affected All versions < V3.0
Siemens · SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)affected All versions < V4.03
Siemens · SCALANCE W-700 IEEE 802.11n familyaffected All versions < V6.1
Siemens · SCALANCE X-200 family (incl. SIPLUS NET variants)affected All versions < V5.2.2
Siemens · SCALANCE X-200IRT family (incl. SIPLUS NET variants)affected All versions < V5.4.0
Siemens · SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)affected All versions < V4.1.0
Siemens · SCALANCE X408 familyaffected All versions < V4.1.0
Siemens · SCALANCE X414affected All versions < V3.10.2
Siemens · SCALANCE XM-400 familyaffected All versions < V6.1
Siemens · SCALANCE XR-500 familyaffected All versions < V6.1
Siemens · SIMATIC CM 1542-1affected All versions < V2.0
Siemens · SIMATIC CM 1542SP-1affected All versions < V1.0.15

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD